  "resourceType" : "AuditEvent",
  "id" : "ex-auditPrivacyDisclosure-recipient",
  "meta" : {
    "profile" : [
      🔗 "https://profiles.ihe.net/ITI/BALP/StructureDefinition/IHE.BasicAudit.PrivacyDisclosure.Recipient"
    ],
    "security" : [
      {
        "system" : "http://terminology.hl7.org/CodeSystem/v3-ActReason",
        "code" : "HTEST"
      }
    ]
  },
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: AuditEvent</b><a name=\"ex-auditPrivacyDisclosure-recipient\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource AuditEvent &quot;ex-auditPrivacyDisclosure-recipient&quot; </p><p style=\"margin-bottom: 0px\">Profile: <a href=\"StructureDefinition-IHE.BasicAudit.PrivacyDisclosure.Recipient.html\">Audit Event for a Privacy Disclosure as recorded by a Recipient</a></p><p style=\"margin-bottom: 0px\">Security Labels: <span title=\"{http://terminology.hl7.org/CodeSystem/v3-ActReason http://terminology.hl7.org/CodeSystem/v3-ActReason}\">http://terminology.hl7.org/CodeSystem/v3-ActReason</span></p></div><p><b>type</b>: Import (Details: DICOM code 110107 = 'Import', stated as 'Import')</p><p><b>subtype</b>: Disclose Record Lifecycle Event (Details: http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle code disclose = 'Disclose Record Lifecycle Event', stated as 'Disclose Record Lifecycle Event')</p><p><b>action</b>: C</p><p><b>recorded</b>: Apr 29, 2020, 4:49:00\u202fAM</p><p><b>outcome</b>: 0</p><p><b>purposeOfEvent</b>: patient requested <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.3.0/CodeSystem-v3-ActReason.html\">ActReason</a>#PATRQT)</span></p><blockquote><p><b>agent</b></p><p><b>type</b>: Source Role ID <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://hl7.org/fhir/R4/codesystem-dicom-dcim.html\">DICOM</a>#110153)</span></p><p><b>who</b>: <span>: myMachine.example.org</span></p><p><b>requestor</b>: false</p><h3>Networks</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Address</b></td><td><b>Type</b></td></tr><tr><td style=\"display: none\">*</td><td>2001:0db8:85a3:0000:0000:8a2e:0370:7334</td><td>2</td></tr></table></blockquote><blockquote><p><b>agent</b></p><p><b>type</b>: Destination Role ID <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://hl7.org/fhir/R4/codesystem-dicom-dcim.html\">DICOM</a>#110152)</span></p><p><b>who</b>: <a href=\"Device-ex-device.html\">Device/ex-device</a></p><p><b>requestor</b>: false</p><h3>Networks</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Address</b></td><td><b>Type</b></td></tr><tr><td style=\"display: none\">*</td><td>http://server.example.com/fhir</td><td>5</td></tr></table></blockquote><blockquote><p><b>agent</b></p><p><b>type</b>: Patient Advocate <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#429577009)</span></p><p><b>who</b>: <a href=\"Patient-ex-patient.html\">Patient/ex-patient</a> &quot; SCHMIDT&quot;</p><p><b>requestor</b>: true</p></blockquote><h3>Sources</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Site</b></td><td><b>Observer</b></td><td><b>Type</b></td></tr><tr><td style=\"display: none\">*</td><td>server.example.com</td><td><a href=\"Device-ex-device.html\">Device/ex-device</a></td><td>Application Server (Details: http://terminology.hl7.org/CodeSystem/security-source-type code 4 = 'Application Server', stated as 'Application Server')</td></tr></table><blockquote><p><b>entity</b></p><p><b>what</b>: <a href=\"Patient-ex-patient.html\">Patient/ex-patient</a> &quot; SCHMIDT&quot;</p><p><b>type</b>: Person (Details: http://terminology.hl7.org/CodeSystem/audit-entity-type code 1 = 'Person', stated as 'Person')</p><p><b>role</b>: Patient (Details: http://terminology.hl7.org/CodeSystem/object-role code 1 = 'Patient', stated as 'Patient')</p></blockquote><blockquote><p><b>entity</b></p><p><b>what</b>: <a href=\"DocumentReference-ex-documentreference.html\">DocumentReference/ex-documentreference</a></p><p><b>type</b>: System Object (Details: http://terminology.hl7.org/CodeSystem/audit-entity-type code 2 = 'System Object', stated as 'System Object')</p><p><b>role</b>: Report (Details: http://terminology.hl7.org/CodeSystem/object-role code 3 = 'Report', stated as 'Report')</p></blockquote></div>"
  },
  "type" : {
    "system" : "http://dicom.nema.org/resources/ontology/DCM",
    "code" : "110107",
    "display" : "Import"
  },
  "subtype" : [
    {
      "system" : "http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle",
      "code" : "disclose",
      "display" : "Disclose Record Lifecycle Event"
    }
  ],
  "action" : "C",
  "recorded" : "2020-04-29T09:49:00.000Z",
  "outcome" : "0",
  "purposeOfEvent" : [
    {
      "coding" : [
        {
          "system" : "http://terminology.hl7.org/CodeSystem/v3-ActReason",
          "code" : "PATRQT",
          "display" : "patient requested"
        }
      ]
    }
  ],
  "agent" : [
    {
      "type" : {
        "coding" : [
          {
            "system" : "http://dicom.nema.org/resources/ontology/DCM",
            "code" : "110153",
            "display" : "Source Role ID"
          }
        ]
      },
      "who" : {
        "display" : "myMachine.example.org"
      },
      "requestor" : false,
      "network" : {
        "address" : "2001:0db8:85a3:0000:0000:8a2e:0370:7334",
        "type" : "2"
      }
    },
    {
      "type" : {
        "coding" : [
          {
            "system" : "http://dicom.nema.org/resources/ontology/DCM",
            "code" : "110152",
            "display" : "Destination Role ID"
          }
        ]
      },
      "who" : {
        🔗 "reference" : "Device/ex-device"
      },
      "requestor" : false,
      "network" : {
        "address" : "http://server.example.com/fhir",
        "type" : "5"
      }
    },
    {
      "type" : {
        "coding" : [
          {
            "system" : "http://snomed.info/sct",
            "code" : "429577009",
            "display" : "Patient Advocate"
          }
        ]
      },
      "who" : {
        🔗 "reference" : "Patient/ex-patient"
      },
      "requestor" : true
    }
  ],
  "source" : {
    "site" : "server.example.com",
    "observer" : {
      🔗 "reference" : "Device/ex-device"
    },
    "type" : [
      {
        "system" : "http://terminology.hl7.org/CodeSystem/security-source-type",
        "code" : "4",
        "display" : "Application Server"
      }
    ]
  },
  "entity" : [
    {
      "what" : {
        🔗 "reference" : "Patient/ex-patient"
      },
      "type" : {
        "system" : "http://terminology.hl7.org/CodeSystem/audit-entity-type",
        "code" : "1",
        "display" : "Person"
      },
      "role" : {
        "system" : "http://terminology.hl7.org/CodeSystem/object-role",
        "code" : "1",
        "display" : "Patient"
      }
    },
    {
      "what" : {
        🔗 "reference" : "DocumentReference/ex-documentreference"
      },
      "type" : {
        "system" : "http://terminology.hl7.org/CodeSystem/audit-entity-type",
        "code" : "2",
        "display" : "System Object"
      },
      "role" : {
        "system" : "http://terminology.hl7.org/CodeSystem/object-role",
        "code" : "3",
        "display" : "Report"
      }
    }
  ]
}