Patient Identifier Cross-referencing for mobile (PIXm)
3.1.0 - Trial-Implementation International flag

This page is part of the IHE Patient Identifier Cross-referencing for Mobile (v3.1.0: Publication) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version. For a full list of available versions, see the Directory of published versions

OperationDefinition: IHE PIXm $pix Operation

Official URL: https://profiles.ihe.net/ITI/PIXm/OperationDefinition/IHE.PIXm.pix Version: 3.1.0
Standards status: Trial-use Maturity Level: 5 Computable Name: IHE_PIXm_pix

The OperationDefinition defines the In and Output Parameters for the $ihe-pix operation

  • Input: sourceIdentifier, targetSystem and _format
  • Output: targetIdentifier, targetId

URL: [base]/Patient/$ihe-pix

Parameters

UseNameScopeCardinalityTypeBindingDocumentation
INsourceIdentifier1..1string
(token)

The Patient identifier search parameter that will be used by the Patient Identifier Cross-reference Manager to find cross matching identifiers associated with the Patient Resource. See Section 3.83.4.1.2.1.

INtargetSystem0..*string
(uri)

The target Patient Identifier Assigning Authority from which the returned identifiers should be selected. See Section 3.83.4.1.2.2.

IN_format0..1string
(token)

The requested format of the response. See ITI TF-2: Appendix Z.6

OUTtargetIdentifier0..*Identifier

The identifier found. Constraints to include the assigning authority as specified in ITI TF-2: Appendix E.3

OUTtargetId0..*Reference

The URL of the Patient Resource