Mobile access to Health Documents (MHD)
4.2.1 - Trial-Implementation International flag

This page is part of the IHE Mobile Access to Health Documents (v4.2.1: Publication) based on FHIR R4. This is the current published version. For a full list of available versions, see the Directory of published versions

CapabilityStatement: Document Source (publisher) implementing UnContained References Option

Official URL: https://profiles.ihe.net/ITI/MHD/CapabilityStatement/IHE.MHD.DocumentSource.UnContained Version: 4.2.1
Active as of 2023-08-02 Computable Name: IHE_MHD_DocumentSource_UnContained

IHE ITI Mobile access to Health Documents (MHD) - Document Source (publisher) - with UnContained Option.

This is the Requirements CapabilityStatement for a Document Source with the UnContained Reference declared Option. This actor must use either Comprehensive Metadata Option or UnContained Reference or UnContained Reference Option. Note that the UnContained Reference Option can not be used with XDS on FHIR Option.

The Document Source uses the Provide Document Bundle ITI-65 to communicate metadata and documents to the Document Recipient.

Provide Document Bundle [ITI-65]Document SourceDocument Recipient1Request to publish documents [ITI-65]2validate content received3propigate to Grouped Actor (e.g. XDS Provide and Register)4Documents published [ITI-65]


Figure: Provide Document Bundle Interactions

Raw OpenAPI-Swagger Definition file | Download

IHE_MHD_DocumentSource_UnContained

IHE ITI Mobile access to Health Documents (MHD) - Document Source (publisher) - with UnContained Option.

ModeCLIENT
Description
Transactiony
System History
System Search
Resource TypeProfileReadSearchUpdateCreate