Mobile Antepartum Summary
1.0.0-comment - ballot
This page is part of the Mobile Antepartum Summary (v1.0.0-comment: Publication Ballot 1) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version. For a full list of available versions, see the Directory of published versions
Official URL: https://profiles.ihe.net/PCC/mAPS/StructureDefinition/IHE.FetalHeartRateUltrasound | Version: 1.0.0-comment | |||
Active as of 2024-06-04 | Computable Name: FetalHeartRateUltrasound |
Fetal Heart rate determined by ultrasound
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from Observation
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | 0..* | Observation | Measurements and simple assertions | |
status | 1..1 | code | registered | preliminary | final | amended + Required Pattern: final | |
category | 1..1 | CodeableConcept | Classification of type of observation Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: exam | |
code | 1..1 | CodeableConcept | Type of observation (code / type) Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 11948-7 | |
effective[x] | 1..1 | dateTime | Clinically relevant time/time-period for observation | |
performer | 1..* | Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) | Who is responsible for the observation | |
value[x] | 1..1 | Quantity | Actual result | |
system | 0..1 | uri | System that defines coded unit form Required Pattern: http://unitsofmeasure.org | |
code | 0..1 | code | Coded form of the unit Required Pattern: /min | |
method | 0..1 | CodeableConcept | How it was done Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 278292003 | |
display | 1..1 | string | Representation defined by the system Fixed Value: Ultrasound imaging - action | |
Documentation for this format |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | 0..* | Observation | Measurements and simple assertions obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
status | ?!Σ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required): Codes providing the status of an observation. Required Pattern: final |
category | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: exam | |
code | Σ | 1..1 | CodeableConcept | Type of observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 11948-7 | |
effective[x] | Σ | 1..1 | dateTime | Clinically relevant time/time-period for observation |
performer | Σ | 1..* | Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) | Who is responsible for the observation |
value[x] | ΣC | 1..1 | Quantity | Actual result |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
system | ΣC | 0..1 | uri | System that defines coded unit form Required Pattern: http://unitsofmeasure.org |
code | Σ | 0..1 | code | Coded form of the unit Required Pattern: /min |
method | 0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 278292003 | |
display | 1..1 | string | Representation defined by the system Fixed Value: Ultrasound imaging - action | |
Documentation for this format |
Path | Conformance | ValueSet / Code | URI |
Observation.status | required | Pattern: finalhttp://hl7.org/fhir/ValueSet/observation-status|4.0.1 from the FHIR Standard | |
Observation.category | preferred | Pattern: examhttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | |
Observation.code | example | Pattern: LOINC Code 11948-7http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | |
Observation.value[x].comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | |
Observation.method | example | Pattern: SNOMED-CT Code 278292003("Ultrasound imaging - action")http://hl7.org/fhir/ValueSet/observation-methods from the FHIR Standard |
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Observation | C | 0..* | Observation | Measurements and simple assertions obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present | ||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | Σ | 0..* | Identifier | Business Identifier for observation | ||||
basedOn | Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | ||||
partOf | Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | ||||
status | ?!Σ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required): Codes providing the status of an observation. Required Pattern: final | ||||
category | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: exam | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
code | Σ | 1..1 | CodeableConcept | Type of observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 11948-7 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
subject | Σ | 0..1 | Reference(Patient | Group | Device | Location) | Who and/or what the observation is about | ||||
focus | Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | ||||
encounter | Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | ||||
effective[x] | Σ | 1..1 | dateTime | Clinically relevant time/time-period for observation | ||||
issued | Σ | 0..1 | instant | Date/Time this version was made available | ||||
performer | Σ | 1..* | Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) | Who is responsible for the observation | ||||
value[x] | ΣC | 1..1 | Quantity | Actual result | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
value | Σ | 0..1 | decimal | Numerical value (with implicit precision) | ||||
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
unit | Σ | 0..1 | string | Unit representation | ||||
system | ΣC | 0..1 | uri | System that defines coded unit form Required Pattern: http://unitsofmeasure.org | ||||
code | Σ | 0..1 | code | Coded form of the unit Required Pattern: /min | ||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
note | 0..* | Annotation | Comments about the observation | |||||
bodySite | 0..1 | CodeableConcept | Observed body part Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. | |||||
method | 0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. Required Pattern: At least the following | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 278292003 | |||||
display | 1..1 | string | Representation defined by the system Fixed Value: Ultrasound imaging - action | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
specimen | 0..1 | Reference(Specimen) | Specimen used for this observation | |||||
device | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | |||||
referenceRange | C | 0..* | BackboneElement | Provides guide for interpretation obs-3: Must have at least a low or a high or text | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
low | C | 0..1 | SimpleQuantity | Low Range, if relevant | ||||
high | C | 0..1 | SimpleQuantity | High Range, if relevant | ||||
type | 0..1 | CodeableConcept | Reference range qualifier Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range. | |||||
appliesTo | 0..* | CodeableConcept | Reference range population Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to. | |||||
age | 0..1 | Range | Applicable age range, if relevant | |||||
text | 0..1 | string | Text based reference range in an observation | |||||
hasMember | Σ | 0..* | Reference(Observation | QuestionnaireResponse | MolecularSequence) | Related resource that belongs to the Observation group | ||||
derivedFrom | Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence) | Related measurements the observation is made from | ||||
component | Σ | 0..* | BackboneElement | Component results | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | Σ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. | ||||
value[x] | Σ | 0..1 | Actual component result | |||||
valueQuantity | Quantity | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
Documentation for this format |
Path | Conformance | ValueSet / Code | URI | |||
Observation.language | preferred | CommonLanguages
http://hl7.org/fhir/ValueSet/languages from the FHIR Standard | ||||
Observation.status | required | Pattern: finalhttp://hl7.org/fhir/ValueSet/observation-status|4.0.1 from the FHIR Standard | ||||
Observation.category | preferred | Pattern: examhttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | ||||
Observation.code | example | Pattern: LOINC Code 11948-7http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | ||||
Observation.value[x].comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | ||||
Observation.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | ||||
Observation.bodySite | example | SNOMEDCTBodyStructureshttp://hl7.org/fhir/ValueSet/body-site from the FHIR Standard | ||||
Observation.method | example | Pattern: SNOMED-CT Code 278292003("Ultrasound imaging - action")http://hl7.org/fhir/ValueSet/observation-methods from the FHIR Standard | ||||
Observation.referenceRange.type | preferred | ObservationReferenceRangeMeaningCodeshttp://hl7.org/fhir/ValueSet/referencerange-meaning from the FHIR Standard | ||||
Observation.referenceRange.appliesTo | example | ObservationReferenceRangeAppliesToCodeshttp://hl7.org/fhir/ValueSet/referencerange-appliesto from the FHIR Standard | ||||
Observation.component.code | example | LOINCCodes (a valid code from LOINC)http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | ||||
Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard |
This structure is derived from Observation
Differential View
This structure is derived from Observation
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | 0..* | Observation | Measurements and simple assertions | |
status | 1..1 | code | registered | preliminary | final | amended + Required Pattern: final | |
category | 1..1 | CodeableConcept | Classification of type of observation Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: exam | |
code | 1..1 | CodeableConcept | Type of observation (code / type) Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 11948-7 | |
effective[x] | 1..1 | dateTime | Clinically relevant time/time-period for observation | |
performer | 1..* | Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) | Who is responsible for the observation | |
value[x] | 1..1 | Quantity | Actual result | |
system | 0..1 | uri | System that defines coded unit form Required Pattern: http://unitsofmeasure.org | |
code | 0..1 | code | Coded form of the unit Required Pattern: /min | |
method | 0..1 | CodeableConcept | How it was done Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 278292003 | |
display | 1..1 | string | Representation defined by the system Fixed Value: Ultrasound imaging - action | |
Documentation for this format |
Key Elements View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | 0..* | Observation | Measurements and simple assertions obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
status | ?!Σ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required): Codes providing the status of an observation. Required Pattern: final |
category | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: exam | |
code | Σ | 1..1 | CodeableConcept | Type of observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 11948-7 | |
effective[x] | Σ | 1..1 | dateTime | Clinically relevant time/time-period for observation |
performer | Σ | 1..* | Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) | Who is responsible for the observation |
value[x] | ΣC | 1..1 | Quantity | Actual result |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
system | ΣC | 0..1 | uri | System that defines coded unit form Required Pattern: http://unitsofmeasure.org |
code | Σ | 0..1 | code | Coded form of the unit Required Pattern: /min |
method | 0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 278292003 | |
display | 1..1 | string | Representation defined by the system Fixed Value: Ultrasound imaging - action | |
Documentation for this format |
Path | Conformance | ValueSet / Code | URI |
Observation.status | required | Pattern: finalhttp://hl7.org/fhir/ValueSet/observation-status|4.0.1 from the FHIR Standard | |
Observation.category | preferred | Pattern: examhttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | |
Observation.code | example | Pattern: LOINC Code 11948-7http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | |
Observation.value[x].comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | |
Observation.method | example | Pattern: SNOMED-CT Code 278292003("Ultrasound imaging - action")http://hl7.org/fhir/ValueSet/observation-methods from the FHIR Standard |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Observation | C | 0..* | Observation | Measurements and simple assertions obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present | ||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | Σ | 0..* | Identifier | Business Identifier for observation | ||||
basedOn | Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | ||||
partOf | Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | ||||
status | ?!Σ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required): Codes providing the status of an observation. Required Pattern: final | ||||
category | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: exam | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
code | Σ | 1..1 | CodeableConcept | Type of observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 11948-7 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
subject | Σ | 0..1 | Reference(Patient | Group | Device | Location) | Who and/or what the observation is about | ||||
focus | Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | ||||
encounter | Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | ||||
effective[x] | Σ | 1..1 | dateTime | Clinically relevant time/time-period for observation | ||||
issued | Σ | 0..1 | instant | Date/Time this version was made available | ||||
performer | Σ | 1..* | Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) | Who is responsible for the observation | ||||
value[x] | ΣC | 1..1 | Quantity | Actual result | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
value | Σ | 0..1 | decimal | Numerical value (with implicit precision) | ||||
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
unit | Σ | 0..1 | string | Unit representation | ||||
system | ΣC | 0..1 | uri | System that defines coded unit form Required Pattern: http://unitsofmeasure.org | ||||
code | Σ | 0..1 | code | Coded form of the unit Required Pattern: /min | ||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
note | 0..* | Annotation | Comments about the observation | |||||
bodySite | 0..1 | CodeableConcept | Observed body part Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. | |||||
method | 0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. Required Pattern: At least the following | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 278292003 | |||||
display | 1..1 | string | Representation defined by the system Fixed Value: Ultrasound imaging - action | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
specimen | 0..1 | Reference(Specimen) | Specimen used for this observation | |||||
device | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | |||||
referenceRange | C | 0..* | BackboneElement | Provides guide for interpretation obs-3: Must have at least a low or a high or text | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
low | C | 0..1 | SimpleQuantity | Low Range, if relevant | ||||
high | C | 0..1 | SimpleQuantity | High Range, if relevant | ||||
type | 0..1 | CodeableConcept | Reference range qualifier Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range. | |||||
appliesTo | 0..* | CodeableConcept | Reference range population Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to. | |||||
age | 0..1 | Range | Applicable age range, if relevant | |||||
text | 0..1 | string | Text based reference range in an observation | |||||
hasMember | Σ | 0..* | Reference(Observation | QuestionnaireResponse | MolecularSequence) | Related resource that belongs to the Observation group | ||||
derivedFrom | Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence) | Related measurements the observation is made from | ||||
component | Σ | 0..* | BackboneElement | Component results | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | Σ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. | ||||
value[x] | Σ | 0..1 | Actual component result | |||||
valueQuantity | Quantity | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
Documentation for this format |
Path | Conformance | ValueSet / Code | URI | |||
Observation.language | preferred | CommonLanguages
http://hl7.org/fhir/ValueSet/languages from the FHIR Standard | ||||
Observation.status | required | Pattern: finalhttp://hl7.org/fhir/ValueSet/observation-status|4.0.1 from the FHIR Standard | ||||
Observation.category | preferred | Pattern: examhttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | ||||
Observation.code | example | Pattern: LOINC Code 11948-7http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | ||||
Observation.value[x].comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | ||||
Observation.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | ||||
Observation.bodySite | example | SNOMEDCTBodyStructureshttp://hl7.org/fhir/ValueSet/body-site from the FHIR Standard | ||||
Observation.method | example | Pattern: SNOMED-CT Code 278292003("Ultrasound imaging - action")http://hl7.org/fhir/ValueSet/observation-methods from the FHIR Standard | ||||
Observation.referenceRange.type | preferred | ObservationReferenceRangeMeaningCodeshttp://hl7.org/fhir/ValueSet/referencerange-meaning from the FHIR Standard | ||||
Observation.referenceRange.appliesTo | example | ObservationReferenceRangeAppliesToCodeshttp://hl7.org/fhir/ValueSet/referencerange-appliesto from the FHIR Standard | ||||
Observation.component.code | example | LOINCCodes (a valid code from LOINC)http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | ||||
Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard |
This structure is derived from Observation
Other representations of profile: CSV, Excel, Schematron